Products / Amplifiers / Single Channel, USB

USB220

By FUTEK

• USB 2.0 Communication Link
• Sampling Rate: up to 4800 Samples Per Second
• Up to ±300,000 count (noise-free)
• mV/V input (selectable up to ±400 mV/V)
• Up to 16 Point Stored Calibration
• ASCII stream output
• High resolution, high accuracy, and low non-linearity
• CE approval and RoHS compliant

Send me a qoutation

Description

The new USB220 – External USB Kit module eliminates the need for an analog amplifier, power supply, and display equipment. The module is supplied by PC power through a USB Cable, providing excitation voltage for the sensor. The analog output voltage of the sensor is then digitized and processed by a microprocessor using the integrated high resolution (24 bits) analogue to digital converter (ADC). The on-board USB transmitter and receiver device allows the microprocessor to communicate with the PC by means of the USB link. The USB integration works hand in hand with SENSIT Test and Measurement software, which allows users to monitor the actual output of the sensor in real time. This is calculated based on the calibration values stored in the on-board memory. The easy plug-and-play connection gives you the power to monitor the sensor output and enjoy measurement that is less affected by noise, temperature variation, and excitation. The USB220 product is designed and manufactured by FUTEK in the USA.

    • Product Highlights
    • USB 2.0 Communication Link
    • Sampling Rate: up to 4800 Samples Per Second
    • Up to ±300,000 count (noise-free)
    • mV/V input (selectable up to ±400 mV/V)
    • Up to 16 Point Stored Calibration
    • ASCII stream output
    • High resolution, high accuracy, and low non-linearity
    • Red Powder Coated
    • CE approval and RoHS compliant
    • EN 61326-1:2006 Criteria A Certification for Aerospace and Medical Grade Devices
  • Product Highlights

    • USB 2.0 Communication Link
    • Sampling Rate: up to 4800 Samples Per Second
    • Up to ±300,000 count (noise-free)
    • mV/V input (selectable up to ±400 mV/V)
    • Up to 16 Point Stored Calibration
    • ASCII stream output
    • High resolution, high accuracy, and low non-linearity
    • CE approval and RoHS compliant
    NAME MIN TYP MAX UNIT
     Excitation  4.6  Vdc
     Nonlinearity  -0.01  0.01  % of R.O.
     Operating Temperature  -13  185
     Sample Rate  10  4800  Samples / Sec
     Communication Interface  USB
     Power Supply  5  Vdc
     Storage Temperature  -40  257
     Input Range  -4  4  mV/V nom.
     Bridge Resistance  50  5000
     Weight  10  Gram

Downloads